Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
1.
Forensic Sci Med Pathol ; 20(1): 100-105, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37060536

RESUMEN

Ramipril is a popular angiotensin-converting enzyme inhibitor applied in the treatment of hypertension. Its therapeutic effect is oriented on the concentration of the active metabolite ramiprilat. The information about toxic drug levels is missing in the literature. Therefore, the aim of this work was an indication of possible toxic ranges based on the analysis of real samples with high ramiprilat concentrations. For these purposes, an appropriate analytical LC-MS/MS method was developed and validated according to forensic guidelines and applied in the routine. Most real samples targeted for ramipril/ramiprilat were associated with the typical therapeutic drug range of 1-40 ng/mL described in the literature. However, higher drug levels with ramiprilat concentrations above 100 ng/mL could also be observed infrequently in cases of driving under the influence of drugs or attempted suicides. To the best of the author's knowledge, this is the first time antemortem ramipril and ramiprilat concentrations associated with driving under the influence of drugs and suicide attempts were discussed from a forensic point of view. The collected data enabled an indication of the ramiprilat toxic concentration range from about 600 ng/mL to at least 3500 ng/mL. The toxic concentration range discussed can be applied in the forensic practice as a reference for future cases.


Asunto(s)
Ramipril/análogos & derivados , Espectrometría de Masas en Tándem , Humanos , Cromatografía Liquida , Toxicología Forense
2.
J Forensic Sci ; 69(2): 725-729, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38146811

RESUMEN

An analytical strategy for identification by an LC-MS/MS multitarget screening method and a suitable LC-MS/MS based quantification were developed for the psychotropic drug phenibut. The samples analyzed were collected during traffic control and were associated with driving under the influence of drugs. A positive sample for phenibut was identified in a single case of driving under the influence. The quantification revealed a drug concentration of 1.9 µg/mL. An interaction with blood alcohol (BAC = 0.10%) was discussed as the explanation of the way of driving and deficit manifestations observed (swaying, nystagmus, quivering of the eyelid, and reddened eyes). According to the available information, the quantified phenibut concentration could be explained by an intake of four tablets (self-reported) during the day containing 250 mg of the drug. Chromatography was performed with a Luna 5 µm C18 (2) 100 A, 150 mm × 2 mm analytical column, and a buffer system consisted of 10 mM ammonium acetate and 0.1% acetic acid (v/v) included in mobile phases marked as A (H2 O/methanol = 95/5, v/v) and B (H2 O/methanol = 3/97, v/v). An effective limit of detection (LOD = 0.002 µg/mL) could be achieved for the multitarget screening method. The quantification of phenibut was performed on a second LC-MS/MS system with LOD/LOQ values of 0.22/0.40 µg/mL. Since phenibut quantification data are rare, the presented information can be used with caution for evaluation of positive cases in the future.


Asunto(s)
Metanol , Espectrometría de Masas en Tándem , Ácido gamma-Aminobutírico/análogos & derivados , Humanos , Cromatografía Liquida/métodos , Espectrometría de Masas en Tándem/métodos , Cromatografía Líquida de Alta Presión/métodos
3.
Dtsch Arztebl Int ; 120(31-32): 526-533, 2023 08 07.
Artículo en Inglés | MEDLINE | ID: mdl-37278091

RESUMEN

BACKGROUND: Serial killing by doctors or nurses is rare. When it occurs, it is generally only detected after multiple homicides by the same perpetrator have escaped detection in the past. The persons at greatest risk are multimorbid elderly patients whose sudden death for natural reasons would not come as a surprise. However, patients' risk of falling victim to homicide is increased only if such vulnerable patients are exposed to perpetrators with certain personality traits. In this situation, homicides can be committed in which little or no evidence of the crime is left behind. In this review, we address the frequency, nature, and circumstances of serial killings and attempted serial killings in hospitals, nursing homes, and nursing care. METHODS: This review is based on publications retrieved by a selective review of the literature in monographs, medical databases, specialty journals, general-interest media, and the Internet. RESULTS: An evaluation of searchable, published case descriptions of serial killings and attempted serial killings in hospitals, nursing homes, and nursing care, mainly from Europe and the English-speaking countries, enables identification of the type of patients at risk, the modes of homicide, and the personality traits of the perpetrators. Multimorbid, care-dependent and nursing-dependent persons are the main victims. The perpetrators (men and women) generally act alone and have often been working in patient care for many years. The most common method of homicide is by drug injection; violent physical homicide is rarer. In many cases, irregularities in drug stocks, erratic behavior of a staff member, and/or a cluster of sudden deaths are indeed noticed, but are too slowly acted upon. CONCLUSION: Irregularities in drug stocks, inexplicably empty drug packages and used syringes, erratic behavior of a staff member before and after a patient's death, or a cluster of unexpected deaths mainly involving elderly, multimorbid patients (detectable from internal mortality statistics) should always lead to further questioning and investigation.


Asunto(s)
Homicidio , Atención de Enfermería , Masculino , Humanos , Femenino , Anciano , Casas de Salud , Hospitales , Causas de Muerte
4.
Drug Test Anal ; 14(6): 1149-1154, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-34997698

RESUMEN

Since rodenticides represent a substance group relevant in toxicological analyses, the aim of this work was the development of a complex multi-target screening strategy for the identification with liquid chromatography-tandem mass spectrometry. A simple protein precipitation was used as the sample preparation strategy. Further, a Luna 5 µm C18 (2) 100 Å, 150 × 2 mm analytical column was applied for the separation of relevant analytes with a Shimadzu HPLC. Signal detection was performed with a SCIEX API 5500 QTrap MS/MS system. The rodenticides investigated (α-chloralose, brodifacoum, bromadiolone, coumatetralyl, difenacoum, and warfarin) could be incorporated effectively into a multi-target screening strategy covering about 250 substances representing different groups with a limit of detection appropriate for substance identification. The strategy can easily be modified to perform semi-quantitative measurements for this substance group and could be supplemented by quantification based on standard addition.


Asunto(s)
Rodenticidas , Anticoagulantes/análisis , Cromatografía Líquida de Alta Presión/métodos , Cromatografía Liquida/métodos , Toxicología Forense , Rodenticidas/análisis , Rodenticidas/química , Espectrometría de Masas en Tándem/métodos
5.
J Anal Toxicol ; 46(6): 676-682, 2022 Jul 14.
Artículo en Inglés | MEDLINE | ID: mdl-34283214

RESUMEN

The aim of the work was the development and validation of a liquid chromatography-tandem mass spectrometry (LC-MS-MS) γ-hydroxybutyrate (GHB) quantification method in urine and human serum by the use of the analyte adduct ion formation strategy. A combined detection with a conventional precursor ion in the negative electrospray mode and additionally GHB adduct ions with both sodium acetate and lithium acetate was in focus. Therefore, GHB quantification was based on separated MS-MS signals. Two tandem mass spectrometers representing different MS-MS generations (Sciex API 4000 QTrap and Sciex API 5500 QTrap) were used for method validation and comparison. Shimadzu HPLC systems equipped with a Luna 5-µm C18 (2) 100 A, 150-mm × 2-mm analytical column were successfully applied for sample analyses. Infusion experiments were performed for adduct identification and analyte detection optimization. Sample preparation could be limited to a simple and fast protein precipitation/sample dilution. An effective signal-separated GHB quantification with three independent precursor ions representing separated areas of the mass spectrum was developed, validated according to forensic guidelines and applied in the routine. The developed and applied strategy resulted in a higher safety factor for the analyte quantification performed in the forensic toxicology. A relevant analytical improvement could be achieved with this alternative adduct-based GHB analysis since a good correlation of analyte concentrations calculated on the basis of separated signals was stated as useful analytical information.


Asunto(s)
Oxibato de Sodio , Espectrometría de Masas en Tándem , Cromatografía Liquida/métodos , Humanos , Iones , Límite de Detección , Reproducibilidad de los Resultados , Espectrometría de Masas en Tándem/métodos
6.
Drug Test Anal ; 14(3): 539-544, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34142460

RESUMEN

Dirty Sprite, also known as "lean" or "purple drank", is a preparation associated with the presence of codeine and promethazine. These drinks, predominantly used by young people, are mixtures of, for example, soft drinks, prescription medicines, and prescription cough syrups. The use of these illicit preparations started in Texas in the 1960s and become popularized in the 1990s. However, the misuse of these cocktails has become more common in other countries to date, for example, in Thailand. Given the illicit nature of these preparations and the lack of information available on the composition of these products, there is a need to identify and quantify the drugs that may be present. Three samples of Dirty Sprite were analyzed using GC-MS after liquid/liquid-extraction under acidic and basic conditions. Since the acidic extraction did not show the detection of relevant substances, samples were alkalized to pH ≥ 9, followed by extraction with 1-chlorobutane. GC-MS screening revealed the identification of codeine, dihydrocodeine, promethazine and impurities of cocaine. A selected ion monitoring method was developed for the quantification of these compounds using lemonade as a calibration matrix. Quantitative analysis showed concentrations of 130-mg/L codeine, 75-mg/L promethazine, and 3.4-mg/L cocaine in sample 1; 74-mg/L promethazine and 91-mg/L dihydrocodeine in sample 2; and 130-mg/L codeine combined with 68-mg/L promethazine in sample 3. The results also illustrate that the consumption of drugs detected in Dirty Sprite samples could lead to health risks given that these prescription medicines are consumed outside the medical environment.


Asunto(s)
Cocaína , Extracción Líquido-Líquido , Adolescente , Cromatografía de Gases y Espectrometría de Masas , Humanos , Espectrometría de Masas/métodos , Preparaciones Farmacéuticas
7.
Bioanalysis ; 13(22): 1671-1679, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34743582

RESUMEN

Aim: Since the MS/MS based detection of small-molecule drugs with poor or even no ion fragmentation is a challenge in bioanalysis, alternative MS/MS detection strategies were in focus of this study and applied in the field of forensic toxicology. Material & methods: Analyte quantification with liquid chromatography-tandem mass spectrometry of problematic drugs was studied by the application of dimer adduct formation and valproic acid (VPA) was used as a model drug. VPA adduct ions could be identified during infusion experiments and the VPA dimer adduct ion was optimized for the detection. Conclusion: Dimer adduct ion formation can be used as an effective way of VPA quantification in human serum. Further, the parallel detection of dimer adduct ions with other adduct ion types can be stated as advantage in LC-MS/MS analysis of problematic drugs.


Asunto(s)
Preparaciones Farmacéuticas/sangre , Bibliotecas de Moléculas Pequeñas/análisis , Espectrometría de Masas en Tándem , Calibración , Cromatografía Líquida de Alta Presión/normas , Dimerización , Humanos , Preparaciones Farmacéuticas/química , Preparaciones Farmacéuticas/normas , Bibliotecas de Moléculas Pequeñas/química , Espectrometría de Masas en Tándem/normas , Ácido Valproico/sangre , Ácido Valproico/química
8.
Drug Metab Pers Ther ; 36(3): 233-237, 2021 03 29.
Artículo en Inglés | MEDLINE | ID: mdl-34412172

RESUMEN

OBJECTIVES: Since melperone abuse with lethal intoxication is common, expert opinions based on therapeutical and lethal concentration ranges can be considered as important. Because there is a lack of information about fatalities caused by melperone mono-intoxications and data on tissue samples with concentration distribution, the aim of this work is the examination of lethal concentration ranges of melperone and drug quantification in different matrices. METHODS: An LC-MS/MS method was applied for analyses performed in blood and tissue samples. Quantification based on standard addition and sample preparation on liquid-liquid extraction with 1-chlorobutane. An appropriate tissue homogenization was performed ahead of extraction with an IKA Ultra-Turrax-Tube-Drive®. A Luna 5 µm C18 (2) 100 Å, 150  × 2 mm analytical column was used for chromatographic separation and the elution was performed with two mobile phases consisted of A (H2O/methanol = 95/5, v/v) and B (H2O/methanol = 3/97, v/v) both with 10 mM ammonium acetate and 0.1% acetic acid. RESULTS: A multi-drug LC-MS/MS analytical method developed was applied successfully for melperone quantification in different post-mortem matrices. No analytical problems could be identified during method development and analyses of real samples. The melperone lethal concentration calculated in femoral blood of the drug mono-intoxication investigated was 10 mg/L. Melperone concentration distribution was presented for the first time. CONCLUSIONS: The lethal reference concentration of melperone in femoral blood of 17.1 mg/L pointed out in different reference lists should be used with caution. Instead, a lower lethal melperone concentration should be considered. The post-mortem concentration distribution of the drug presented could be helpful in the interpretation of cases where no blood samples are available.


Asunto(s)
Butirofenonas , Espectrometría de Masas en Tándem , Cromatografía Líquida de Alta Presión/métodos , Cromatografía Liquida/métodos , Humanos , Extracción Líquido-Líquido , Espectrometría de Masas en Tándem/métodos
9.
Drug Test Anal ; 13(7): 1318-1330, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-33723920

RESUMEN

In this publication, benzodiazepines, opioids, and further drugs were analyzed in exhumed brain and liver tissue samples in 116 cases (total) after 9.5-16.5 years of burial. Solid phase extraction followed by liquid chromatography-tandem mass spectrometry was applied. Data from literature is listed summarizing the detectability of the presented analytes after a certain time of burial. In our study, 60% of the analyzed benzodiazepines, 100% of the opioids, and 82% of further drugs were detectable. Only the benzodiazepines lorazepam, nitrazepam, flunitrazepam, and its metabolite norflunitrazepam, and the drugs butylscopolamine, metronidazole, and omeprazole were not detectable at all. Percentage of positive findings (total, and separately for brain and liver tissue) and postmortem period are listed for each analyte. Correlation of detectability depending on postmortem period and condition of tissue are presented exemplarily for midazolam. No substantial correlation was observed. Despite a long time of burial, most benzodiazepines, opioids, and further drugs were detectable in the examined tissue samples. Our results may be a good support for future exhumations in which toxicological analyses are relevant.


Asunto(s)
Analgésicos Opioides/análisis , Benzodiazepinas/análisis , Cromatografía Liquida/métodos , Espectrometría de Masas en Tándem/métodos , Adulto , Anciano , Anciano de 80 o más Años , Encéfalo/metabolismo , Exhumación , Femenino , Humanos , Hígado/metabolismo , Masculino , Persona de Mediana Edad , Preparaciones Farmacéuticas/análisis , Extracción en Fase Sólida , Factores de Tiempo , Distribución Tisular
10.
Drug Metab Pers Ther ; 2021 Mar 26.
Artículo en Inglés | MEDLINE | ID: mdl-33770824

RESUMEN

OBJECTIVES: Since melperone abuse with lethal intoxication is common, expert opinions based on therapeutical and lethal concentration ranges can be considered as important. Because there is a lack of information about fatalities caused by melperone mono-intoxications and data on tissue samples with concentration distribution, the aim of this work is the examination of lethal concentration ranges of melperone and drug quantification in different matrices. METHODS: An LC-MS/MS method was applied for analyses performed in blood and tissue samples. Quantification based on standard addition and sample preparation on liquid-liquid extraction with 1-chlorobutane. An appropriate tissue homogenization was performed ahead of extraction with an IKA Ultra-Turrax-Tube-Drive®. A Luna 5 µm C18 (2) 100 Å, 150  × 2 mm analytical column was used for chromatographic separation and the elution was performed with two mobile phases consisted of A (H2O/methanol = 95/5, v/v) and B (H2O/methanol = 3/97, v/v) both with 10 mM ammonium acetate and 0.1% acetic acid. RESULTS: A multi-drug LC-MS/MS analytical method developed was applied successfully for melperone quantification in different post-mortem matrices. No analytical problems could be identified during method development and analyses of real samples. The melperone lethal concentration calculated in femoral blood of the drug mono-intoxication investigated was 10 mg/L. Melperone concentration distribution was presented for the first time. CONCLUSIONS: The lethal reference concentration of melperone in femoral blood of 17.1 mg/L pointed out in different reference lists should be used with caution. Instead, a lower lethal melperone concentration should be considered. The post-mortem concentration distribution of the drug presented could be helpful in the interpretation of cases where no blood samples are available.

11.
Drug Test Anal ; 13(3): 595-603, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33017092

RESUMEN

This paper should serve as support for future exhumations in which an analysis of cardiovascular drugs is issued after over 9 years of burial. Amiodarone, amlodipine, atropine, bisoprolol, cafedrine, clonidine, esmolol, furosemide, hydrochlorothiazide, lisinopril, nifedipine, nitrendipine, phenprocoumon, torsemide verapamil, and xipamide were determined in liver and brain tissue of over 100 cases in which exhumation was performed after over 9 years of burial. Diagrams, showing the detectability depending on postmortem period as well as condition of tissues, are presented for furosemide.


Asunto(s)
Fármacos Cardiovasculares/análisis , Cromatografía Liquida/métodos , Cambios Post Mortem , Espectrometría de Masas en Tándem/métodos , Adulto , Anciano , Anciano de 80 o más Años , Encéfalo/metabolismo , Exhumación , Femenino , Humanos , Hígado/metabolismo , Masculino , Persona de Mediana Edad , Extracción en Fase Sólida , Factores de Tiempo
14.
Drug Metab Pers Ther ; 32(3): 147-150, 2017 09 26.
Artículo en Inglés | MEDLINE | ID: mdl-28787270

RESUMEN

BACKGROUND: As imatinib gained a lot of attention in the field of medicine, appropriate methods are needed for drug analysis. LC-MS/MS combined with complex sample preparation and column enrichment is usually the method of choice when high sensitivity is necessary. The application of LC-MS3 in imatinib quantification has not been discussed in the literature. METHODS: An LC-MS3 imatinib quantification method was developed and validated in human serum. The sample preparation was based on the liquid-liquid extraction of 50 µL human serum. Chromatographic separation was performed using a Luna 5 µm C18 (2) 100 A, 150 mm×2 mm column and the elution was done using a mobile phase consisting of A (H2O/methanol=95/5, v/v) and B (H2O/methanol=3/97, v/v), both with 10 mM ammonium acetate and 0.1% acetic acid. RESULTS: The conditions applied resulted in a limit of detection/quantification value of 0.14/0.45 ng/mL reached without a sophisticated sample preparation technique or enrichment column application. It could be demonstrated that MS3 detection is a very effective way of sensitive imatinib quantification. Further, it could be stated that the strategy presented can be very useful for a sensitive analysis of other protein kinase inhibitors, because their molecule structure is appropriate for MS3 detection. CONCLUSIONS: The presented analytical strategy is an effective way of protein kinase inhibitor analysis in human serum.


Asunto(s)
Cromatografía Liquida/métodos , Mesilato de Imatinib/sangre , Inhibidores de Proteínas Quinasas/sangre , Espectrometría de Masas en Tándem/métodos , Humanos , Extracción Líquido-Líquido
17.
J Forensic Sci ; 61 Suppl 1: S250-1, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26358275

RESUMEN

This study highlights the problem of levamisole-adulterated cocaine in context of active traffic participation. For the purposes of levamisole concentration monitoring in human serum, an analytical method based on LC-MS/MS and solid-phase extraction was applied. A Luna 5 µm C18 (2) 100 A, 150 mm × 2 mm column and a mobile phase consisting of A (H2 O/methanol = 95/5, v/v) and B (H2 O/methanol = 3/97, v/v), both with 10 mM ammonium acetate and with 0.1% acetic acid (pH = 3.2), were used. The validation experiments demonstrated that the method applied was appropriate for levamisole quantification in human serum. For 23% of levamisole-positive samples, the concentrations exceeded 20 ng/mL. Therefore, the interaction of this drug with cocaine has to be considered as important for active traffic participation. As a consequence, monitoring of levamisole concentration in human serum is recommended, as long as it is used as cocaine adulterant.


Asunto(s)
Trastornos Relacionados con Cocaína , Cocaína/sangre , Contaminación de Medicamentos , Levamisol/sangre , Cromatografía Líquida de Alta Presión , Cromatografía Liquida , Humanos , Reproducibilidad de los Resultados , Espectrometría de Masas en Tándem
20.
Artículo en Inglés | MEDLINE | ID: mdl-24747522

RESUMEN

A valproic acid (VPA) LC-MS/MS analytical method using analyte adduct formation was developed and validated in human serum. The fragmentation of the sodium acetate adduct (mass transition: 225/143) and acetic acid adduct (mass transition: 203/143) were used as the target and qualifier mass transition, respectively. A Luna 5 µm C18 (2) 100 A, 150 mm×2 mm analytical column and a mobile phase consisting of A (H2O/methanol=95/5, v/v) and B (H2O/methanol=3/97, v/v), both with 10mM ammonium acetate and 0.1% acetic acid (pH=3.2) were used. A binary flow pumping mode with a total flow rate of 0.4 mL/min was applied. Protein precipitation with 1 mL of the mobile phase B was used as sample preparation. The calculated limit of detection/quantification was 0.45/1.0 µg/mL and the inter-/intra-day precision was <6%. The application of a deuterated internal standard resulted in a good adduct formation reproducibility. The strategy applied made the VPA LC-MS/MS analysis in human serum on the basis of two mass transitions possible. Therefore, it is an interesting alternative for the VPA pseudo multiple reaction monitoring methods (mass transition 143/143) and a proof that the developed strategy is also useful for the analysis of compounds which do not produce any stable ion fragments detectable by tandem mass spectrometry.


Asunto(s)
Anticonvulsivantes/sangre , Cromatografía Liquida/métodos , Espectrometría de Masas en Tándem/métodos , Ácido Valproico/sangre , Anticonvulsivantes/química , Humanos , Estructura Molecular , Ácido Valproico/química
SELECCIÓN DE REFERENCIAS